Infrared image of radiant cooling system at Lambert Residence, in Los Gatos CA.
House is tested in radiant cooling mode.
*Measurements*
Outdoor temperature 85F
Average indoor radiant temperature 73F
Average active ceiling panel temperatures 59-65F
Supply water temperature 49F
Average dew point 52F
High ceiling with wood ceiling beams attached on top of the Ray Magic panels. The ceiling height goes from 9 to 14 ft.
This system utilizes three geothermal heat pumps to generate heated and chilled water for use within a radiant floor system for radiant heating and cooling. Additionally, Messana Controls was used to integrate with Mitsubishi VRF units to provide cooling!
Installed by the team at Warm Corp West, this mechanical room serves a 15,720 sqft residence in the Bay Area. The home's 4-pipe hydronic system utilizes a single air-to-water heat pump to generate chilled water for hydronic cooling, while two boilers produce hot water for hydronic heating.